CAS
740 Monitor
The CAS 740 vital-signs monitor
for all your patients, from neonatal to adult.
The range includes both hospital monitors and portable (paramedic) units available
in a variety of configurations. The newest monitor is the CAS 740 and is available
as both mains and 12V versions. This multi-parameter monitor delivers accuracy,
reliability and ease of use. Designed to meet all subacute and paramedic applications,
it is ideal for medical/surgical patients on the wards, or for spot checks
on Admissions Units.
The CAS 740 monitor offers leading
edge technology in a rugged, lightweight, portable
unit. Fast, accurate blood pressure is measured through
CAS’s proprietary MAXNIBP technology. Oximetry
choices include Masimo SET pulse oximetry, which
is designed to be accurate during motion and low
perfusion.
The CAS 740 also lets you monitor temperature (optional) eliminating the need
for additional equipment. Yet the CAS 740 weighs only 1500g, operates on either
battery, DC or AC mains power, and is simple to program. It mounts easily on
a cart, IV pole, bedrail or wall. An optional external IR printer puts critical
data at your fingertips.
CAS 740 - NIBP, SpO2
and Temperature
CAS 740 - NIBP and SpO2
CAS 740 - NIBP only
(Each of the above
is also available with an external infra-red
printer).
The CAS 740 monitor employ
reliable CAS MAXNIBP oscillometric non-invasive
blood-pressure measurement and advanced motion
artefact rejection capability to give you an extra
set of safe hands when time is of the essence. 
|
SPECIFICATIONS
NIBP
Technique: Oscillometric (MAXNIBP
Technology)
Patient Range: Adult - Neonate
Measurement Range:
Systolic: 30-255 mmHg
Diastolic: 15-225 mmHg
MAP: 20-235 mmHg
Pulse Rate Rage: 30-240 mmHg
Accuracy: Blood Pressure ± 5 mmHg, standard deviation <8
mmHg
Pulse Rate ± 2% or ± 2 bpm, whichever is greater
Oximetry (Options)
Masimo SET®
SpO2% Range: 0-100%
SpO2 % Accuracy:
70-100%, ± 2 digits
(1S.D.) Adult
70-100%, ± 3 digits (1S.D.) Neonate
Pulse Rate Rage: 25-240 bpm
Pulse Rate Accuracy: ± 3 bpm
Nellcor® Oximax™
SpO2% Range: 1-100%
SpO2 % Accuracy:
70-100%, ± 2 digits (1S.D.) Adult
70-100%, ± 3 digits (1S.D.) Neonate
Pulse Rate Rage: 18-240 bpm
Pulse Rate Accuracy: ± 3% or ± 1 digit, whichever
is greater
Nonin®
SpO2% Range: 0-100%
SpO2 % Accuracy:
70-100%, ± 2 digits (1S.D.) Adult
70-100%, ± 3 digits (1S.D.) Neonate
Pulse Rate Rage: 20-240 bpm
Pulse Rate Accuracy: ± 3 digits
Temperature (optional)
Welch Allyn SureTemp™
Temperature Range: 28.9 to 42.2 °C (84.0 to 108.0 °F)
Accuracy: ± 0.1 °C (± 0.2 °F), meets
or exceeds ASTM
Control Panel
Display: LED display of measurement
results, instructions, troubleshooting messages and
signal strength bar.
Parameters Displayed: Systolic Pressure, Diastolic Pressure,
Mean Arterial Pressure (MAP), Pulse Rate, %SpO2, Temperature
(in °C or °F)
Patient Alarms
Adjustable high and low alarms
for Pulse Rate, %SpO2 , Systolic Pressure, Diastolic
Pressure and Mean Arterial Pressure.
Operating Modes
Measurement: Manual, STAT or Automatic,
Adult and Neonatal.
History: Review of previous measurements
Events: NIBP parameters and Temperature at present intervals.
Trends: 1 minute %SpO2 and Temperature (if continuous) intervals.
Menu: Settings, Tests, etc.
Power
Source: External or internal.
AC: 100-250 VAC, 50-60 Hz, 0.3A, 0.5 A fuse
DC (optional): 12-30 VDC
Battery: Smart NiMH battery pack (removable)
Charge Time: 4 hours
Operating Time: Minimum 4 hours of continuous operation
Leakage Current: 100 µA
(maximum)
Safety Limits
Automatic Cuff Deflation: If cuff
pressure exceeds 290 mmHg (Adults) or 145 mmHg (Neonate).
If measurement time exceeds 120 seconds (Adults) or 90 seconds
(Neonate).
If safety timer detects microprocessor failure.
Operating Environment
Operating Temperature:
0-50 °C (32-122 °F) for NIBP & SpO2
16-40 °C (61-104 °F) for Temperature
Storage Temperature: -20 to 65 °C (-4 to 149 °F)
Humidity: 15-95%, non-condensing
Altitude: Up to 3048 meters (10,000 feet)
Monitors may not meet performance specifications if stored
or used outside temperature and humidity ranges.
Physical Dimensions & Weight
Height x Width x Depth: 170 mm
x 215 mm x 75 mm (6.75 in x 8.5 in x 3 in)
Weight: 1.4 kg (3 lbs)
Standards
Units comply with the following
requirements:
ANSI/AAMI SP10, EN 60601-1, EN 60601-1-2, EN 60601-2-30,
EN 60601-2-49, EN 865, ETL Listed - UL 2601, CAN/CSA C22.2
No.601.1, CE marking according to Directive 93/42/EEC
Optional Accessories
Printer with infrared interface
RS 232 Interface
Swiveled Hard Mount (for ambulance applications)
Roll Stand and Basket
Protective Carrying Case
|