CAS Medical: CAS 740
Request DemonstrationDownload DatasheetSend for more information


CAS 740

CAS 740 Monitor
The CAS 740 vital-signs monitor for all your patients, from neonatal to adult.

The range includes both hospital monitors and portable (paramedic) units available in a variety of configurations. The newest monitor is the CAS 740 and is available as both mains and 12V versions. This multi-parameter monitor delivers accuracy, reliability and ease of use. Designed to meet all subacute and paramedic applications, it is ideal for medical/surgical patients on the wards, or for spot checks on Admissions Units.

The CAS 740 monitor offers leading edge technology in a rugged, lightweight, portable unit. Fast, accurate blood pressure is measured through CAS’s proprietary MAXNIBP technology. Oximetry choices include Masimo SET pulse oximetry, which is designed to be accurate during motion and low perfusion.

The CAS 740 also lets you monitor temperature (optional) eliminating the need for additional equipment. Yet the CAS 740 weighs only 1500g, operates on either battery, DC or AC mains power, and is simple to program. It mounts easily on a cart, IV pole, bedrail or wall. An optional external IR printer puts critical data at your fingertips.

CAS 740 - NIBP, SpO2 and Temperature
CAS 740
- NIBP and SpO2
CAS 740 - NIBP only
(Each of the above is also available with an external infra-red printer).

The CAS 740 monitor employ reliable CAS MAXNIBP oscillometric non-invasive blood-pressure measurement and advanced motion artefact rejection capability to give you an extra set of safe hands when time is of the essence.

Masimo SET

SPECIFICATIONS

NIBP
Technique: Oscillometric (MAXNIBP Technology)
Patient Range: Adult - Neonate
Measurement Range:
Systolic: 30-255 mmHg
Diastolic: 15-225 mmHg
MAP: 20-235 mmHg
Pulse Rate Rage: 30-240 mmHg
Accuracy: Blood Pressure ± 5 mmHg, standard deviation <8 mmHg
Pulse Rate ± 2% or ± 2 bpm, whichever is greater

Oximetry (Options)
Masimo SET®
SpO2% Range: 0-100%
SpO2 % Accuracy:
70-100%, ± 2 digits (1S.D.) Adult
70-100%, ± 3 digits (1S.D.) Neonate
Pulse Rate Rage: 25-240 bpm
Pulse Rate Accuracy: ± 3 bpm

Nellcor® Oximax™
SpO2% Range: 1-100%
SpO2 % Accuracy:
70-100%, ± 2 digits (1S.D.) Adult
70-100%, ± 3 digits (1S.D.) Neonate
Pulse Rate Rage: 18-240 bpm
Pulse Rate Accuracy: ± 3% or ± 1 digit, whichever is greater

Nonin®
SpO2% Range: 0-100%
SpO2 % Accuracy:
70-100%, ± 2 digits (1S.D.) Adult
70-100%, ± 3 digits (1S.D.) Neonate
Pulse Rate Rage: 20-240 bpm
Pulse Rate Accuracy: ± 3 digits

Temperature (optional)
Welch Allyn SureTemp™
Temperature Range: 28.9 to 42.2 °C (84.0 to 108.0 °F)
Accuracy: ± 0.1 °C (± 0.2 °F), meets or exceeds ASTM

Control Panel
Display: LED display of measurement results, instructions, troubleshooting messages and signal strength bar.
Parameters Displayed: Systolic Pressure, Diastolic Pressure, Mean Arterial Pressure (MAP), Pulse Rate, %SpO2, Temperature (in °C or °F)

Patient Alarms
Adjustable high and low alarms for Pulse Rate, %SpO2 , Systolic Pressure, Diastolic Pressure and Mean Arterial Pressure.

Operating Modes
Measurement: Manual, STAT or Automatic, Adult and Neonatal.
History: Review of previous measurements
Events: NIBP parameters and Temperature at present intervals.
Trends: 1 minute %SpO2 and Temperature (if continuous) intervals.
Menu: Settings, Tests, etc.

Power
Source: External or internal.
AC: 100-250 VAC, 50-60 Hz, 0.3A, 0.5 A fuse
DC (optional): 12-30 VDC
Battery: Smart NiMH battery pack (removable)
Charge Time: 4 hours
Operating Time: Minimum 4 hours of continuous operation
Leakage Current: 100 µA (maximum)

Safety Limits
Automatic Cuff Deflation: If cuff pressure exceeds 290 mmHg (Adults) or 145 mmHg (Neonate).
If measurement time exceeds 120 seconds (Adults) or 90 seconds (Neonate).
If safety timer detects microprocessor failure.

Operating Environment
Operating Temperature:
0-50 °C (32-122 °F) for NIBP & SpO2
16-40 °C (61-104 °F) for Temperature
Storage Temperature: -20 to 65 °C (-4 to 149 °F)
Humidity: 15-95%, non-condensing
Altitude: Up to 3048 meters (10,000 feet)
Monitors may not meet performance specifications if stored or used outside temperature and humidity ranges.

Physical Dimensions & Weight
Height x Width x Depth: 170 mm x 215 mm x 75 mm (6.75 in x 8.5 in x 3 in)
Weight: 1.4 kg (3 lbs)

Standards
Units comply with the following requirements:
ANSI/AAMI SP10, EN 60601-1, EN 60601-1-2, EN 60601-2-30, EN 60601-2-49, EN 865, ETL Listed - UL 2601, CAN/CSA C22.2 No.601.1, CE marking according to Directive 93/42/EEC

Optional Accessories
Printer with infrared interface
RS 232 Interface
Swiveled Hard Mount (for ambulance applications)
Roll Stand and Basket
Protective Carrying Case


Contact your local Artemis Medical Sales Specialist on 01322 628877 for a demonstration.