Masimo: Sensors, Probes and Accessories

Sensors

Artemis Medical can offer the complete range of Masimo sensors for use with all of the Masimo technology they supply including CAS Medical and Mindray monitors. A complete selection of reusable and single-patient use, latex free adhesive sensors is available for all patients from adults to neonates. The LNOP® (Low Noise Optical Probe) sensors are uniquely designed to assume that noise, both physiological and non-physiological, will be present, and are designed to reduce this noise to further improve the quality of the monitored signal.


Single Patient Adhesive Sensors
l
LNOP II Series
MAS1800
MAS1798
MAS1651
MAS1519
Hold mouse over photo to see probe in use

MAS 1652

weight 3-10 kg

LNOP MAS 1798

weight<10 kg

MAS 1651

weight<1 kg

MAS 1519

weight>30 kg

LNOP Series
MAS1001
MAS1025
MAS1002
MAS1003
Hold mouse over photo to see probe in use

MAS 1001weight>30 kg

MAS 1025weight 10-50 kg

MAS 1002weight>1 hand placed weight<10 foot placed

MAS 1003weight<1

Visit our online shop
Advantages of LNOP Sensors

• Durability
The tape material used in Masimo LNOP adhesive sensors is much more durable than that used in the competitive sensors. The result is a sensor that can be moved and reapplied multiple times during a patient’s stay.

• Rejuvenation Feature
The adhesive used in the Masimo LNOP sensors has a unique rejuvenation feature. Using 70% isopropyl alcohol, the adhesive can be rejuvenated and the stickiness restored.

• Increased Sensor Longevity
Longevity studies have been conducted and the results show a nearly two-fold increase in durability with Masimo LNOP sensors compared to competitive disposable sensors.

• Increasing Performance
Masimo LNOP sensors are uniquely designed to reduce interference from physiologic and non-physiologic noise. Unlike conventional pulse oximetry sensor design, the photodetector is recessed in a cavity that protects it from ambient light interference. The sensors are also designed to decrease the effects of electro-magnetic interference.

Masimo Adhesive Sensors Improves Performance While Reducing Cost

Adhesive sensors have always had clinical advantages over reusable “finger clip” sensors, which have made them the optimal clinical choice of caregivers.

• The risk of cross contamination is less likely from single-patient use adhesive sensors than from reusable sensors.

• For patients who are active or agitated, it is more difficult to shake off an adhesive sensor, thereby making monitoring in high motion environments more effective.

• Compared to reusable sensors, adhesive sensors, which decrease pressure on the monitoring site, are less prone to cause pressure necrosis.Discover for yourself how Masimo adhesive sensors represent an entire “New Evolution” in sensor technology.

Reusable Finger and Ear Sensors

Finger Sensors
MAS1269
MAS1276
MAS1278
MAS1794
Hold mouse over photo to see probe in use

MAS 1269

MAS 1276

MAS 1278

Ear Sensor

Miscellaneous Reusable Sensors and Attachments
MAS 1544 Multisite Sensor
MAS 1596 CleanShield Wrap*
MAS 1597 Standard Wrap*
MAS 1598 Standard Petite Wrap*
MAS 1602 Foam Wrap*

Hold mouse over any of the photos on the right to see this probe in use

MAS 1596weight>1 kg

MAS 1597weight>weight>1 kg

MAS 1598weight>1 hand placed weight<30 foot placed

MAS 1602weight>1 kg

*Multi Site Sensor Attachments: for use with Multi Site Sensor (MAS1544)

Visit our online shop
Masimo SET Sensors: Basic Principles

In high motion, low perfusion or otherwise challenging environments, use of the adhesive LNOP sensors are strongly recommended for optimal performance.

Tips for Use:

• When selecting a sensor site, priority should be given to an extremity free of an arterial catheter, blood pressure cuff or intra-vascular infusion line.

• Ensure that the emitter and detector of the LNOP or NR sensor are properly aligned as outlined in the probe attachment instructions and the Directions For Use.

• As an alternative for infants over 3 kg or with fat or edematous feet, consider use of the LNOP Neo sensor on the big toe. Adhesive sensor sites should be checked at least every eight hours. Reusable sensors must be repositioned every four hours.

• Adhesive sensors may be reapplied to the same patient if the emitter and detector windows are clear and the adhesive still adheres to the skin.

• For use in neonates with particularly fragile skin, the stickiness of the medical grade adhesive can be diminished or eliminated by daubing the adhesive areas with a cotton ball. Reusable sensors should be cleaned between patients.

Cables

Artemis Medical supplies all Masimo's standard cables and adaptors. The AC-1 adaptor cable (MAS 1645) allows certain Nellcor and Nellcor-compatible monitors to use Masimo probes and sensors.

MAS 1173
MAS 1005
MAS 1006
MAS 1795
MAS 1645
CablePCO4 4ft patient cable

Cable

PCO4 8ft patient cable

Cable

PCO4 12ft patient cable
SET Tester with cable