BeneView
T6/T8: no-compromise monitors...
• 15"/17"colour TFT
display
• Suitable for adult, paediatric and neonatal patients
• Up to 3 slave screens on the main units for separate view
• 13 module slots for flexible configuration
• MPM module with up to 8-hour data saving for patient transport
• Advanced technologies including RM, ICG, BIS, etc.
• Maximum 8 channels for IBP measurement
• Friendly and configurable user interface
• Powerful data review:
• Maximum 120-hour graphic and tabular trends of all parameters
• 24-hour full disclosure waveforms review
• 120 seconds frozen waveforms
• Up to 1000 pieces of NIBP record storage
• 100 pieces of regular alarms review
• 100 pieces of ARR alarms storage
• Ethernet or Wireless LAN networking |
|
 |
Standard
Configuration:
• Main unit + Display + MPM (ECG,
SpO2, Dual-IBP, 2-TEMP, NIBP)
Optional:
All-in-one Module: MPM with optional configurations
Single Modules: 12 lead ECG module, Dual-IBP
module, CO module, EtCO2 module, Multi-gas/O2 module(with
optional BIS), ICG module, BIS module, Spirometry module,
Thermal recorder module
Module Racks: 8 slot module rack
Navigating options: touch screen, mouse,
keyboard, or Bluetooth presenter.
Other options:
Wireless LAN, Power-off Storage, Laser
Printer, External Displays |
|
 |
 |
|
|
|
Technical
Specifications
Safety
Meets the requirements of IEC60601 series,
Dimension and Weight
Dimension: 400mm(W)x370mm(H)X193mm(D)
Weight:10.5 (standard configuration)
Operational Environment
Power requirements: AC100-240(±10%)
50/60Hz(±3Hz),2.5-1.4A
Temperarure: 5-40oC
Humidity: 15-95%
Patient Range
Adult, pediatric and neonatal
Performance Specifications
Display: 15"/17"(T6/T8)color XGA/SXGA
Support up 4 independent displays
Multi slave display selectable
Trace: Waveform channel per display 10/12(T6/T8)
More than 40 waveforms with
Independent displays
Sweep speed: 6,25mm/s, 12.5mm/s, 25mm/s, and 50mm/s
Indicator: Dual alarm indicator lights
Power indicator light
Battery idicator light
QRS beep and alarm sound
Operating key sound
Interface: Parameter module frame and interface
AC Power input socket
Network interface
External display interface (DVI)
Aux output interface
Defib sync interface
Peripheral USB Device
(mouse, keyboard, Bluetooth presenter, etc)
Battery backup: Rechargeable battery Li-ion battery
2hours working time
Trend time: 120 hours trending
Up to 24 hours full disclousure
Alarm: User-adjustable High and low limits
Prioritized audiable and visual alarm
Networking: Connected to central monitoring system by hardwire/wireless
Bedside device connection
Connected to Clinical Information System
(Currently only available in China)
Recorder: Built-in, thermal array
Waveform: 3 channels
Printer: External printer supported
ECG
5-lead and 3 lead selectable, 12-lead optional
Input: 10-leadwire: RA;LA;RL;LL;V1-V6
5-leadwire cable: RA;LA;RL;LL;V
3-leadwire cable: RA;LA;LL
Lead selection: 12 lead: I,II,III;aVR,aVL,aVF,V1-V6
5-lead: I,II,III;aVR,aVL,aVF,V(n)
3-lead: I,II,III
ECG waveform: Up to 8 channels, 12 lead display
Gain selection: x0.125;x0.25;x0,5;x1;x2;auto
Sweep speed: 12,5mm/s, 25mm/s, 50 mm/s
Heart Rate range: Adult: 15-300 bpm;
Neonante/Pediatric 15-350bpm
Accuracy:±1bpm or ±1%, whichever is greater
Resolution: 1bpm
Filter: Diagnostic mode: 0.05-150Hz
Monitoring mode: 0.5-40 Hz
Surgical mode: 1-20 Hz
Protection: Withstand 4000VAC/50Hz voltage in isolation
Against electrosurgical interference and defibrillation
Scalling signal: 1mV ±5%
Alarm range: 15-350bpm
S-T segment detection: Measurement range: -2.0mV~2.0V
Alarm range: -2.0mV~2.0mV
Arythmia analysis: yes
Alarm: Yes, audiable and visual alarm
alarm events recallable
12 lead ECG Analysis: yes
Resipiration
Method: Thoracic impedance
Operation modes: Auto/Manual
Measurement range: Adult: 0~120 rpm
Neonate/Pediatric: 0~150 rpm
Accuracy: 7-150 rpm ±2rpm or ±2% whichever is greater
0~6 rpm unspecified
Alarm: Yes, audieble and visual alarm
alarm events recallable
NIBP
Method: Automatic oscillometric
Operation modes: Manual/Automatic/Continuous
Auto measure time: Adjustable
Measurement unit: mmHg/kPa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement range:
Range of systolic pressure AdultMode 40-270mmHg
Pediatric Mode 40-200mmHg
Neonatal Mode 40-135 mmHg
Range of diastolic pressure Adult Mode 10-210mmHg
Pediatric Mode 10-150mmHg
Neonatal Mode: 10-100mmHg
Range of mean pressure Adult Mode 20-230mmHg
Pediatric Mode 20-165mmHg
Neonatal Mode 20-110mmHg
Accuracy of blood pressure measurement
The mean error shall be less than ±5mmHg
The standard deviation shall be less than 8mmHg
Over pressure protection: double safety protection
Resolution: 1mmHg
Alarm: Systolic, Diastolic, Mean
SpO2
Mindray SpO2
Measurement range: 0~100%
Resolution: 1%
Accuracy: ±2%(70-100%, Adult/PediatricNon-motion)
±3%(70-100%, Neonate, non-motion)
±3%(70-100%, Adult/Pediatric/Neonate, motion)
0-69% unspecified
Alarm range: 0-100%
Pulse rate: Range: 20~254bpm
Resolution: 1bpm
Accuracy: ±3bpm(non-motion)
±5bpm (motion)
Alarm range: 20~254bpm
MASIMO SpO2
Measurement range 1-100%
Resolution: 1%
Accuracy: ±2%(70-100%, Adult/PediatricNon-motion)
±3%(70-100%, Neonate, non-motion)
±3%(70-100%, Adult/Pediatric/Neonate, motion)
0-69% unspecified
Alarm range: 1-100%
Pulse rate: Range: 25~240bpm
Resolution: 1bpm
Accuracy: ±3bpm(non-motion)
±5bpm (motion)
Alarm range: 25~240bpm
NELLCOR SpO2
Measurement range: 0~100%
Resolution: 1%
Accuracy: 2%(70-100%, MAX-A,MAX-AL,MAX-N,
MAX-P,MAX-I and MAX FAST sensors)
2,5%(70-100%, OxiCliq A, OxiCliq N, OxiCliq I sensors)
3%(70-100%,D-YS, DS-100A, OXI-A/N and OXI-P/I Sensors)
3.5%(70-100%, MAX-R, D-YSE and D-YSPD sensors)
0-69% unspecified
Alarm range: 0-100%
Pulse rate: Range: 20~300bpm
Resolution: 1bpm
Accuracy: 20-250bpm ±3bpm
251-300bpm unpecified
Alarm range: 20~250bpm
Temperature
Measurement range 0~50oC
Resolution 0.1oC
Accuracy: ±0.1oC
Invasive blood pressure (IBP)
Measurement range: -50~300mmHg
|
|
Channel: up to 2 channels
Pressure transducer: Sensitivity: 5mV/V/mmHg
Impedance range: 300-3000W
Pressure names: ART, PA, CVP, RAP, LAP, ICP, CPP
Resolution: 1mmHg
Accuracy: ±2% or ±1mmHg, whichever is greater(exclusive of transducer)
Alarm range: -50~300mmHg
Cardiac Output
Method: Thermodilution
Measurements range: CO;01-20L/min.
TB:23-43oC
TI:0-27oC
Resolution: CO:0.1L/min
TI: 0.1oC
TB: 0.1oC
Accuracy: CO:±5%
TB:±0.1oC
TI: ±0.1oC
Parameter output: Cardiac output
Hemodynamics calculation
EtCO2
Method: Infrared absorption
Displayed numerics: EtCO2, FICO2, AwRR
Waveforms: Capnography
Microstream CO2
CO2 range 0-99mmHg
Accuracy: 0-38 mmHg ±2mmHg
39-99mmHg ±5% of reading + 0.08% for every 1mmHg
(above 38mmHg)
Resolution: Waveform:0.1 mmHg Value: 1mmHg
Sampling rate 50ml/min-7.5+15ml/min
Initialization time 30 seconds (typical), reaches ±5%
steady-state accuracy within 3 minutes
Response time Typical value: 2.9s, including the rising
time and the delay time
(adopting the FilterLine of standard length)
Rising time: <190ms(rising from 10% to 90%)
Delay time: 2.7s (typical value)
Respiration rate 0-150 rpm
Respiration rate accuracy 0-70rpm ±1rpm
71-120rpm ±2rpm
121-150rpm ±3rpm
Modde: Adult, noenate
Sidestream CO2
CO2 measurement range 0-99mmHg
Accuracy ±2mmHg(0-40mmhg)
±5% of reading (41-76mmHg)
±10% of reading (77-99mmHg)
Sampling rate: 100 or 150 ml/min
Sampling rate accuracy 15%
Start up line <1min, once the modul starts up
it reaches ISO accuracy Mode 10 minutes after
start up, the module reaches full accuracy mode
Respiration rate 0-120rpm
Respiration rate accuracy ±2rpm(0-70rpm)
±5rpm(70rpm)
Response time <240msec(10% to 90%)
Delay time <2s (Sampling line length: 7 inches; internal
diameter:0.055 inches
sampling gas flow rate:150ml/min)
Mainstream CO2
Method: Infrared Absorpion
Measuring Mode: Mainstream
Measuremnt Range: CO2:0-150mmHg
AwRR: 0-150 rpm
Resolution:CO2:0-69mmHg; 0.1mmHg AwRR:1rpm
Accuracy: CO2 concentration:
±2mmHg (0-40mmHg)
±5% of reading (41-70mmHg)
±8% of reading (71-100mmHg)
±10% of reading (101-150mmHg)
Alarm range: Same as Measurement range
Multi-Gas/O2
Method:Infrared Absorption/Paramagnetic
Gas sorts: CO2, N2O, Des, Iso, Enf, Sev, Hal
O2 (optional paramagnetic sensor)
Measurement range: CO2:0-30%
N2O:0-105%
O2:0-105%
Enf, ISO, Hal: 0-30%
Sev:0-30%
Des:0-30%
Measurement accuracy: CO2:0-1%±0,1%, 1-5%±0.2%, 5-7%
0.3%, 7-10%±0.5%,>10%unspecified
N2O:0-20%±2%, 20-100%±3%
Des:0-1%±0.15%, 1-5%±0.2%, 5-10%±0.4%, 10-15%±0.4%
10-15%±0.6%,15-18%±1%>18unspecified.
Sev:0-1%±0.15,1-5%±0.2%, 5-8%±0.4,>8unspecified.
Enf. Iso,Hal:0-1%±0.15%, 1-5%±0.2%,>5unspecified
O2;0-25%±1%,25-80%±2%;80-100±3%
Data output: Fiand ET values
Respiration rate: ±1rpm(2-60rpm)
Unspecified(61-100rpm)
Alarm: User selectable alarm limits for all Measurements
Other: Up to 5 waveforms displayed
Agent mixture detection
MAC value displayed
Bispectral Index(BIS)
Method: EEG Bispectrum analysis, DSA
BIS range: 0-100
SQI range: 0-100%
Other calculated parameters: Signal Quality Index(SQI), EMG
Suppression Ratio(SR), TP
BIS smooth rate: 15s or 30s (default)
EEG specifications: EEG scales: 6.25uV/12.5uV/25uV/50uV/100uV
Sweep speeds:12.5/25/50 mm/sec
Noise (RTI):<03uVRMS 0.25-50Hz
Input range:±1mV
EEG Bandwith: 0.25-110Hz
A/D Conversion: Noise shaped Sigma-Delta
Sample Rate: 16.384 samples/seconds
Patient Leakage:<10uA
Impedance Cardiography(ICG)
Method: Thoracicrange: Bioimpedance measurement
DISQTM (Digital Impedance Signal Qualifier) Technology
Z MARC (Impedance Modulating AoRtic Compliance) algorithm
Waveforms: Thoracic Bioimpedance
Stroke Volume(SV)range: 5-250ml/b
Heart rate (HR) range: 44-185bpm
Cardiac Output(CO)range: 1,4-15l/min
Other measured parameters: Flow, Resistance, Contractility, Fluid
Status and Cardiac Work Parameters:
SI, CI, BSA,SVR/SVRI,PVR/PVRI,LCW/LCWI,LVSW/LVSWI,RCW/RCWI
RVSW/RVSWI,EF,ACI,VI,TFC,TFI,STR,PEP,LVET,VEPT.
Alarm: User selectable alarm limits for TFC, CI
Respiratory Mechanics(RM)
Method: Flow measurement based on micro
differential pressure sensing
Waveforms: Airway Pressure, Flow, Volume, Loops (P-V,V-F)
Flow: Range: Aldult, Pediatric:±(2-120)l/min
Neonate:±(0.5-30)l/min
Accuracy:25ml/s or ±10% of reading
Whichever is greater
Resolution: 0.1l/min
Pressure unit: User selectable cmH2O, kPs, or mmHg
Airway pressure: Range:-20.0 to 120.0 cmH2O
Accuracy: ±3% of reading
Resolution: 0.1 cmH2O
Minute volume: Range: Adult, Pediatric:2-60l/min
Neonate: 0.5-15l/min
Accuracy: ±5% of reading
Tidal volume: Range: Adult, Pediatric:100-1500ml
Neonate: 20-500ml
Resolution:1ml
Accuracy:±5% of reading
Respiration Rate: Range: Adult, Pediatric: 4-99rpm
Neonate:10-99rpm
Accuracy:±2rpm
I:E ratio Range: 12.0:1 - 1:12.0
Accuracy:±5% of reading
Dead space:<11ml
Other Measured parameters: Respiratory Mechanics parameters: I:E ratio
FEV 1.0,MAP,TVi/TVe,
MVi/MVe,PEEP,PEF,PIF,PIP,C,Compliance,RAW,RSBI,NIP,WOB.
Alarm: User selectable alarm limits for Respiration Rate,PEEP,PIP,Mve
|
Beneview Options
Main unit: Main unit with integrated display, power supply and navigating lever
Main unit with integrated display, touchscreen, power supply, and navigating lever
All-In-One Module: Stand-of-Care MPM modules (6 kind of options)
Parameter Modules: Dual IBP module, CO module, EtCO2 module, Multi-Gas/O2 modules(with optional BIS module),
Respiratpry Mechanics Module
Module Rack: 8 slot module rack
Navigating Options: USB compatible mouse, keyboard, Bluetooth presenter
Printing Options: 3 channel thermal recorder module , printer
Mounting Options: Rolling stand, wall mount
Other Options: External Display, Wireless LAN, Power off Storage & Extensive memory card
Model Selections
| |
BeneView T6 |
BeneView T8 |
| Integrated Display |
15" color TFT |
17" color TFT |
| External independent display support |
standard: 1, Option:3 |
standard:3 |
|
| Waveform channel |
Standard 10(up to 40 with independent displays) |
12(up to 48 with independent displays) |
| Touch screen operation |
Optional |
Optional |
| MPM Module
| Compatible |
Compatible |
| External module frame |
Compatible |
Compatible |
| IBP measurement |
Up to 8 channels |
Up to 8 channels |
| Data trending
| Up to 120 hrs |
Up to 120 hrs |
| Full disclousure review & Power-off storage |
Optional |
Standard |
| Calculations |
Standard: 2 kinds, Drug & Homodynamic Calculation |
Standard: 5 kinds, Drug, Homodynamic, Oxygen, Ventilation, Nephritic |
MPM Module Options:
| |
M1 |
M2 |
M3 |
M4 |
M5 |
M6 |
| 3/5-lead ECG
| x |
x |
x |
x |
x |
x |
| 12-lead ECG |
|
|
|
x |
x |
x |
| RESP |
x |
x |
x |
x |
x |
x |
| Dual channel TEMP |
x |
x |
x |
x |
x |
x |
| NIBP |
x |
x |
x |
x |
x |
x |
| Dual channel IBP |
x |
x |
x |
x |
x |
x |
| Mindray SPO2 |
x |
|
|
x |
|
|
| Masimo SPO2 |
|
x |
|
|
x |
|
| Nellcor SPO2 |
|
|
x |
|
|
x |
Multi-Gas/O2 Module Option
| |
GAS1 |
GAS2 |
GAS3 |
GAS4 |
GAS5 |
GAS6 |
GAS7 |
GAS8 |
| Auto-ID AG |
x |
x |
x |
x |
|
|
|
|
| Manual-ID AG |
|
|
|
|
x |
x |
x |
x |
| O2 |
x |
x |
|
|
x |
x |
|
|
| BIS |
x |
|
x |
|
x |
|
x |
|
NOTE: specifications
subject to change without prior notice
| Contact
your local Artemis Medical Sales Specialist on 01322 62 88 77
for further information. |
|