Mindray: Beneview T5 Request DemonstrationDownload DatasheetSend for more information




Features:

• 12.1" color TFT display

• Suitable for adult, pediatric and neonatal patients

• 13 module slots for flexible configuration

• Advanced technologies including RM, ICG, BIS, etc.

• Maximum 8 channels for IBP measurement

• Friendly and configurable user interface

• Ethernet or Wireless LAN networking

• Powerful data review:

Bebeview T5

 

Maximum 120-hour graphic and tabular trends of all parameters

 

24-hour full disclosure waveforms review

 

120 seconds frozen waveforms

 

Up to 1000 pieces of NIBP record storage

 

100 pieces of regular alarms review

 

100 pieces of ARR alarms storage


Standard Configuration:

Main unit + Display + MPM(ECG, SpO2, 2-TEMP, NIBP)

Optional:

•All-in-one Module: MPM with optional configurations
• Single Modules: 12 lead ECG module, Dual-IBP module, CO module, EtCO2 module, Multi-gas/O2 module(with optional BIS), ICG module, BIS module, RM module, Thermal recorder module
•Module Racks: 8 slot module rack
•Other options: Wireless LAN, Power-off Storage, Laser Printer, External Displays

NOTE: specifications subject to change without prior notice

 

Technical Specifications

Safety
Meets the requirements of IEC60601 series,

Dimension and Weight

Main unit: 336mm(W) x 297mm(H) x 187mm(D)
Weight: 6.6 kg
MPM: Dimension: 80.5mm(W) x 136,5mmm(H)x 102mm(D)
Weight: 0.63kg (without accessories) SMR: Dimension: 402mm(W) x 142mm(H) x 151mm(D) Weight: 1.8kg

Operational Environment

Power requirements: AC100-240(±10%) 50/60Hz(±3Hz),2.5-1.4A Temperarure: 0-40oC Humidity: 15-95%

Patient Range
Adult, pediatric and neonatal

Performance Specifications

Display: 12.1" color TFT
Resolution: 800x600
Slave display: 1(non-indepentent)
Indepentent display: 2
Trace: Waveform channel per display: up to 8
Sweep speed: 6,25mm/s, 12.5mm/s, 25mm/s, and 50mm/s
Indicator: Dual alarm indicator lights
Power indicator light
AC power indicator light
Battery idicator light
QRS beep and alarm sound
Operating key sound
Interface: AC Power input socket
One SMR connector
One RJ45 connector
One External display inhterface (DVI)
One Aux Output interface (Analog out/Nurse call)
One Defib Sync Interface
Four USB devices interface
(mouse, keyboard, Bluetooth presenter, etc)
One Cis interface (Currently only available in China)
One CF interface
One WLAN interface
Battery backup: Rechargable Li-ion battery
3 hours working time
Trend time: 120 hours trending
Up to 24 hrs full disclousure
Alarm: User-adjustable High and low limits
Prioritized audiable and visual alarm
Networking: Connected to central monitoring system
by hardwire/wireless
Bedside device connection
Connected to Clinical Information System
(Currently only available in China)
Recorder: Built-in, thermal array
Waveform: 3 channels
Printer: External printer supported

ECG

5-lead and 3 lead selectable, 12-lead optional
Input: 10-leadwire: RA;LA;RL;LL;V1-V6
5-leadwire cable: RA;LA;RL;LL;V
3-leadwire cable: RA;LA;LL
Lead selection: 12 lead: I,II,III;aVR,aVL,aVF,V1-V6
5-lead: I,II,III;aVR,aVL,aVF,V(n)
3-lead: I,II,III
ECG waveform: Up to 8 channels, 12 lead display
Gain selection: x0.125;x0.25;x0,5;x1;x2;auto
Sweep speed: 12,5mm/s, 25mm/s, 50 mm/s
Heart Rate range: Adult: 15-300 bpm;
Neonante/Pediatric 15-350bpm
Accuracy:±1bpm or ±1%, whichever is greater
Resolution: 1bpm
Filter: Diagnostic mode: 0.05-150Hz
Monitoring mode: 0.5-40 Hz
Surgical mode: 1-20 Hz
Protection: Withstand 4000VAC/50Hz voltage in isolation
Against electrosurgical interference and defibrillation
Scalling signal: 1mV ±5%
Alarm range: 15-350bpm
S-T segment detection: Measurement range: -2.0mV~2.0V
Alarm range: -2.0mV~2.0mV
Arythmia analysis: yes
Alarm: Yes, audiable and visual alarm
alarm events recallable
12 lead ECG Analysis: yes
Pace detection: yes

Resipiration

Method: Thoracic impedance
Operation modes: Auto/Manual
Measurement range: Adult: 0~120 rpm
Neonate/Pediatric: 0~150 rpm
Accuracy: 7-150 rpm ±2rpm or ±2% whichever is greater
0~6 rpm unspecified
Apnea alarm: yes
Alarm: Yes, audieble and visual alarm
alarm events recallable

NIBP

Method: Automatic oscillometric
Operation modes: Manual/Automatic/Continuous
Auto measure time: Adjustable
Measurement unit: mmHg/kPa selectable Measurement types: Systolic, Diastolic, Mean
Measurement range:
Range of systolic pressure AdultMode 40-270mmHg
Pediatric Mode 40-200mmHg
Neonatal Mode 40-135 mmHg
Range of diastolic pressure Adult Mode 10-210mmHg
Pediatric Mode 10-150mmHg
Neonatal Mode: 10-100mmHg
Range of mean pressure Adult Mode 20-230mmHg
Pediatric Mode 20-165mmHg
Neonatal Mode 20-110mmHg
Accuracy of blood pressure measurement
The mean error shall be less than ±5mmHg
The standard deviation shall be less than 8mmHg
Over pressure protection: double safety protection
Resolution: 1mmHg
Alarm: Systolic, Diastolic, Mean

SpO2
Mindray SpO2

Measurement range: 0~100%
Resolution: 1%
Accuracy: ±2%(70-100%, Adult/PediatricNon-motion)
±3%(70-100%, Neonate, non-motion)
±3%(70-100%, Adult/Pediatric/Neonate, motion)
0-69% unspecified
Alarm range: 0-100%
Pulse rate: Range: 20~254bpm
Resolution: 1bpm
Accuracy: ±3bpm(non-motion)
±5bpm (motion)
Alarm range: 20~254bpm

MASIMO SpO2

Measurement range 1-100%
Resolution: 1%
Accuracy: ±2%(70-100%, Adult/PediatricNon-motion)
±3%(70-100%, Neonate, non-motion)
±3%(70-100%, Adult/Pediatric/Neonate, motion)
0-69% unspecified
Alarm range: 1-100%
Pulse rate: Range: 25~240bpm
Resolution: 1bpm
Accuracy: ±3bpm(non-motion)
±5bpm (motion)
Alarm range: 25~240bpm

NELLCOR SpO2

Measurement range: 0~100%
Resolution: 1%
Accuracy: 2%(70-100%, MAX-A,MAX-AL,MAX-N,
MAX-P,MAX-I and MAX FAST sensors)
2,5%(70-100%, OxiCliq A, OxiCliq N, OxiCliq I sensors)
3%(70-100%,D-YS, DS-100A, OXI-A/N and OXI-P/I Sensors)
3.5%(70-100%, MAX-R, D-YSE and D-YSPD sensors)
0-69% unspecified
Alarm range: 0-100%
Pulse rate: Range: 20~300bpm
Resolution: 1bpm
Accuracy: 20-250bpm ±3bpm
251-300bpm unpecified
Alarm range: 20~250bpm

Temperature

Measurement range 0~50oC
Resolution 0.1oC
Accuracy: ±0.1oC

Invasive blood pressure (IBP)

Measurement range: -50~300mmHg

 

Channel: up to 8 channels
Pressure transducer: Sensitivity: 5mV/V/mmHg
Impedance range: 300-3000W
Pressure names: ART, PA, CVP, RAP, LAP, ICP, CPP
Resolution: 1mmHg
Accuracy: ±2% or ±1mmHg, whichever is greater(exclusive of transducer)
Alarm range: -10~300mmHg

Cardiac Output

Method: Thermodilution
Measurements range: CO;01-20L/min.
TB:23-43oC
TI:0-27oC
Resolution: CO:01L/min
TI: 0.1oC
TB: 0.1oC
Accuracy: CO:±5% or ±0.1L/min, whichever is greater
TB:±0.1oC
TI: ±0.1oC
Parameter output: Cardiac output
Hemodynamics calculation

EtCO2

Displayed numerics: EtCO2, FICO2, AwRR
Waveforms: Capnography

Microstram CO2

CO2 range 0-99mmHg
Accuracy: 0-38 mmHg ±2mmHg
39-99mmHg ±5% of reading + 0.08% for every 1mmHg
(above 38mmHg)
Resolution 1mmHg
Sampling rate 50ml/min-7.5+15ml/min
Initialization time 30 seconds (typical), reaches ±5%
steady-state accuracy within 3 minutes
Response time Typical value: 2.9s, including the rising
time and the delay time
(adopting the FilterLine of standard length)
Rising time: <190ms(rising from 10% to 90%)
Delay time: 2.7s (typical value)
Respiration rate 0-150 rpm
Respiration t rate accuracy 0-70rpm ±1rpm
71-120rpm ±2rpm
121-150rpm ±3rpm
Modde: Adult, noenate

Sidestream CO2

CO2 measurement range 0-99mmHg
Accuracy ±2mmHg(0-40mmhg)
±5% of reading (41-76mmHg)
±10% of reading (77-99mmHg)
Sampling rate 150ml/min
Sampling rate accuracy 15%
Start up line <1min, once the modul starts up
it reaches ISO accuracy Mode 10 minutes after
start up, the module reaches full accuracy mode
Respiration rate 0-120rpm
Respiration rate accuracy ±2rpm(0-70rpm)
±5rpm(70rpm)
Response time <240msec(10% to 90%)
Delay time <2s (Sampling line length: 7 inches; internal
diameter:0.055 inches
sampling gas flow rate:150ml/min)

Mainstream CO2

Method: Infrared Absorpion
Measuring Mode: Mainstream
Measuremnt Range: CO2:0-150mmHg
AwRR: 0-150 rpm
Rosolution: CO2: 1mmHg
Accuracy: CO2 concentration:
±2mmHg (0-40mmHg)
±5% of reading (41-70mmHg)
±8% of reading (71-100mmHg)
±10% of reading (101-150mmHg)
AwRR: 1rpm
Alarm range: Same as Measurement range

Multi-Gas/O2

Method:Infrared Absorption/Paramagnetic
Gas sorts: CO2, N2O, Des, Iso, Enf, Sev, Hal
O2 (optional paramagnetic sensor)
Measurement range: CO2:0-30%
N2O:0-100%
O2:0-100%
Enf, Iso, Hal: 0-30%
Sev:0-30%
Des:0-30%
Measurement accuracy: CO2:0-1%±0,1%, 1-5%±0.2%, 5-7%
0.3%, 7-10%±0.5%,>10%unspecified
N2O:0-20%±2%, 20-100%±3%
Des:0-1%±0.15%, 1-5%±0.2%, 5-10%±0.4%, 10-15%±0.6%
15-18%±1%>18unspecified.
Sev:0-1%±0.15,1-5%±0.2%, 5-8%±0.4,>8unspecified.
Enf. Iso,Hal:0-1%±0.15%, 1-5%±0.2%,>5unspecified O2;0-25%±1%,25-80%±2%;80-100±3%
Data output: Fiand ET values
Respiration rate: ±1rpm(2-60rpm)
Unspecified(61-100rpm)
Alarm: User selectable alarm limits for all Measurements
Other: Up to 5 waveforms displayed
Agent mixture detection
MAC value displayed

Bispectral Index(BIS)

BIS range: 0-100
SQI range: 0-100%
Other calculated parameters: Signal Quality Index(SQI), EMG
Suppression Ratio(SR), TP
BIS smooth rate: 15s or 30s (default)
EEG specifications: EEG scales: 6.25uV/12.5uV/25uV/50uV/100uV
Sweep speeds:12.5/25/50 mm/sec
Noise (RTI):<03uVRMS 0.25-50Hz
Input range:±1mV
EEG Bandwith: 0.25-110Hz
A/D Conversion: Noise shaped Sigma-Delta
Sample Rate: 16.384 samples/seconds
Patient Leakage:<10uA

Impedance Cardiography(ICG)
Method: Thoracicrange: Bioimpedance measurement
DISQTM (Digital Impedance Signal Qualifier) Technology
Z MARC (Impedance Modulating AoRtic Compliance) algorithm
Waveforms: Thoracic Bioimpedance
Stroke Volume(SV)range: 5-250ml/b
Heart rate (HR) range: 44-185bpm
Cardiac Output(CO)range: 1,4-15l/min
Other measured parameters: Flow, Resistance, Contractility, Fluid
Status and Cardiac Work Parameters: CO,
CI,BSA,HR,SV,SI,SVR,SVRI,LCW
LCWI,LVSW,LVSWI,TFC,VEPT,ACI,TFI,PEP,VI,STR,LVET.
Alarm: User selectable alarm limits for TFC, CI

Respiratory Mechanics(RM)

Method: Flow measurement based on micro
differential pressure sensing
Waveforms: Airway Pressure, Flow, Volume, Loops (P-V,V-F)
Flow: Range: Aldult, Pediatric:±(2-120)l/min
Neonate:±(0.5-30)l/min
Accuracy:25ml/s or ±10% of reading
Whichever is greater
Resolution: 0.1l/min
Pressure unit: User selectable cmH2O, kPs, or mmHg
Airway pressure: Range:-20.0 to 120.0 cmH2O
Accuracy: ±3% of reading
Resolution: 0.1 cmH2O
Minute volume: Range: Adult, Pediatric:2-60l/min
Neonate: 0.5-15l/min
Accuracy: ±5% of reading
Tidal volume: Range: Adult, Pediatric:100-1500ml
Neonate: 20-500ml
Resolution:1ml
Accuracy: ±15mL or ±10%of reading whichever is greater
Respiration Rate: Range: 4-120 rpm
Accuracy:4-99rpm:±1rpm
100-120rpm:±2rpm
I:E ratio Range: 4.0:1 - 1:8.0
Accuracy:±10% of reading
Dead space: <11ml
Other measurement parameters: Respiratory Mechanics parameters:
FEV 1.0, Pmean, TVi/TVe,
MVi/MVe, PEEP, PEF, PIF, PIP, Pplat
Compliance, RAW, RSBI, NIP, WOB
Alarm: User selectable alarm limits for
Respiration Rate, PEEP, PIP, MVe


Contact your local Artemis Medical Sales Specialist on 01322 62 88 77 for further information.