Technical Specifications
Safety
Meets the requirements of IEC60601 serials, CE marking according
to MDD93/42/EEC
Size and Weight
Dimensions: 318mm (W) x 264mm (H) x 152mm (D)
Weight: 4 kg
Operation Environment
Power: AC100~250V, 50/60 Hz
Temperature: 0~40 oC
Humidity: 15~95%
Patient Range
Adult, pediatric and neonatal
Performance Specifications
Display: 10.4" color TFT
Resolution :800x600
Trace: 4 waveforms
Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
Indicator: Alarm indicator
Power indicator
QRS beep and alarm sound
Networking: Connected to Mindray Hypervisor III central system
Interface: Net Port
Battery: Rechargeable
Trend time: 1~72 hours
Alarm: 10-level audible and visual alarm
Recorder: Built-in, thermal array, 2 channels
Record width:48 mm (record paper 50 mm)
Record speed:25 mm/s, 50 mm/s
ECG
Input: 3-lead: R; L; F or RA; LA; LL
Lead selection: I; II; III
ECG waveform: 1 channel (the 2nd waveform cascade)
Gain selection: x0.25; x0.5; x1; x2; auto
Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
Heart Rate Range: Adult:15~300bpm
Pediatric/Neonatal:15~350bpm
Accuracy: 1bpm or 1%, whichever is greater
Resolution: 1bpm
Protection: Withstand 4000VAC/50Hz voltage in isolation
against electrosurgical interference and defibrillation
CMRR: Diagnostic mode: >90dB
Monitor mode: >105dB
Surgery mode: >105dB
Operation modes: Diagnostic, Monitor, Surgery
Bandwidth: 0.05~100Hz
Pace Detection: YES
Alarm range: Adult: 15~300bpm
Pediatric/Neonatal:15~350bpm
S-T detection: YES
Measurement range: -2.0mV~2.0mV
Alarm range: -2.0mV~2.0mV
Arrhythmia analysis: YES
Alarm : YES, audible and visual alarm, alarm
Events recallable
|
|
Respiration
Method: Impedance between R-F(RA-LL)
Measurement range: Adult: 0-120rpm
Pediatric/Neonatal: 0-150rpm
Resolution: 1rpm
Accuracy: 2rpm
Alarm range: Adult:0~120rpm
Pediatric/Neonatal: 0-150rpm
Apnea alarm: 10-40(s)
NIBP
Method: Oscillometric
Operation modes: Manual/Automatic/STAT
Measurement unit: mmHg/Kpa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement range: Adult: 10~270mmHg
Pediatric: 10~200mmHg
Neonatal: 10~135mmHg
Over-pressure protection: YES
Resolution: 1mmHg
Accuracy: Mean error and standard deviation
per ANSI/AMI SP-10
Alarm: Systolic, Diastolic, Mean
Temperature (Surface and Intracavity)
Measurement range: 0~50 oC
Resolution: 0.1 oC
Accuracy: 0.1oC(not including probe)
Channel: 1 channel
Alarm range: 0~50 oC
SpO2
Measurement range: 0~100%
Resolution: 1%
Accuracy: 2 %(70~100%); 0~69% unspecified
Alarm range: 0~100%
Pulse Rate:
Range:25~254bpm
Resolution: 1bpm
Accuracy: 2bpm or 2%, whichever is greater
Alarm range: 0-254bpm
NOTE: specifications subject