Technical
Specifications
Safety
Meets the requirements of IEC60601 series, CE marking according
to MDD93/42/EEC
Dimension and Weight
Dimension: 310mm (W) x 280mm (H) x 150mm (D)
Weight: 5.5kg (not including external Multi-gas module)
Operation Environment
Power: AC100-250V, 50/60 Hz
Temperature: 0-40oC
Humidity: 15-95%
Patient Range
Adult, pediatric and neonatal
Performance Specifications
Display: 10.4" color TFT
Resolution: 800x600
Trace: 8 waveforms
Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
Indicator: Alarm indicator
Power indicator
QRS beep and alarm sound
Interface: Net Port
Battery: Rechargeable
Lead-Acid: >45 minutes
Lithium-ion: >90 minutes
Trend time: 1-96 hours
Alarm: 10-level audible and visual alarm
Networking: LAN/Wireless LAN to Mindray Hypervisor III Central
Staion
Wireless LAN: Operates on license free ISM (Industrial, Scientific
and Medical) 2.4 ~ 2.483 GHz radio frequency band
IEEE 802.11b compliant
Recorder: Built-in, thermal array, 2 channels
Record width: 48mm, (record paper 50mm)
Record speed:25mm/s, 50mm/s
ECG
5-lead or 3-lead selectable
Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
3-lead: RA; LA; LL or R; L; F
Lead selection: 5-lead: I; II; III; avR; avL;
avF; Vx I, II, III, aVR, aVL, aVF, V (n)
3-lead: I; II; III
ECG waveform: 2 channels
Gain selection: x0.25; x0.5; x1; x2(mm/mV); auto
Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
Heart Rate range: Adult: 15-300bpm;
Pediatric/Neonatal: 15-350bpm
Accuracy: ±1bpm or ±1%, whichever greater
Protection: Withstand 4000VAC/50Hz voltage
in isolation. Against electrosurgical
interference and defibrillation
CMRR: Diagnostic mode: >90dB
Monitoring mode: >105dB
Operating mode: >105dB
Operation modes: Diagnostic, Monitor, Surgery
Bandwidth: 0.05-100Hz
Alarm range: Adult:15-300bpm
Pediatric/Neonatal: 15-350bpm
S-T detection: YES
Measurement range: -2.0mV~2.0mV
Alarm range: -2.0mV~2.0mV
Arrhythmia analysis: YES
Pace Detection: YES
Alarm: YES, audible and visual alarm, alarm events recallable
Respiration
Method: RA-LL impedance
Measurement range: Adult: 6-120rpm
Pediatric/Neonatal: 6-150rpm
Accuracy: ±2 rpm
Alarm range: Adult: 6-120rpm
Pediatric/Neonatal: 6-150rpm
Apnea alarm: YES
NIBP
Method: Oscillometric
Operation modes: Manual/Automatic/STAT
Measurement unit: mmHg/kPa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement range: Adult: 10-270mmHg
Pediatric: 10-200mmHg
Neonatal: 10-135mmHg
Over-pressure protection: YES
Resolution: 1mmHg
Accuracy: Mean error and standard deviation per
ANSI/AAMI SP-10
Alarm: Systolic, Diastolic, Mean
Temperature
Measurement range: 0-50oC
Resolution: 0.1oC
Accuracy: ±0.1oC (not including probe)
Channel: Dual-channel
Alarm range: 0-50oC
|
|
Mindray SpO2
Measurement range: 0-100%
Resolution: 1%
Accuracy: 70~100% ±2%; 0~69% unspecified
Alarm range: 0-100%
Pulse rate
Range: 0-254bpm
Resolution: 1bpm
Accuracy: ±2bpm (30-250bpm)
Alarm range: 0-254bpm
Masimo SET SpO2
Range
Saturation (SpO2): 1-100%
Pulse Rate: 30-235 bpm
Adult
SpO2 Range: 70%-100% 0% to 69%
Accuracy (±1Std. Dev.)*: ±2 digits Unspecified
Pulse Rate Range: 25-240 bpm
Accuracy (±1Std. Dev.)*: ± 3 bpm
Neonate
SpO2 Range: 70%-95% 0% to 69%
Accuracy (±1Std. Dev.)*: ± 3 Digits Unspecified
Pulse Rate Range: 30-235 bpm
Accuracy (±1Std. Dev.)*: ± 3 bpm
Nellcor SpO2
Measurement Range
SpO2: 1% to 100%
Pulse Rate: 20 to 250 bpm
Accuracy
Saturation (% SpO2 ± SD):
Adults 70% to 100% *±2 digits
Neonates * 70% to 100% ±3 digits
***** 1% to 69% unspecified
Pulse rate: 20 to 250 bpm ±3 digits
IBP
Measurement range: -50~300mmHg
Channel: 2 channels
Pressure transducer: Sensitivity: 5 μV/V/mmHg
Impedance range:>300
Transducer sites: ART, PA, CVP, RAP, LAP, ICP
Measurement unit: mmHg/kPa selectable
Resolution: 1mmHg
Accuracy: ±1mmHg or ±2%, whichever greater
Alarm range: -10~300mmHg
CO
Method: Thermodilution
Measurement range: CO: 0.1-20 lit./min.
TB: 23-43oC
TI: 0-27oC
Resolution: CO: 0.1 lit./min.
Temperature: ±0.1oC
Accuracy: CO: 2%
TB: ± 0.1oC
TI: ± 0.1oC
EtCO2
Method: Infrared Absorption
Measurement Mode: Sidestream or mainstream (optional)
Measurement range: EtCO2: 0-99mmHg
InsCO2:0-99mmHg
AwRR: 0-150rpm
Resolution: EtCO2: 1mmHg
InsCO2:1mmHg
AwRR: 1rpm
Accuracy: CO2 concentration: ±2mmHg (0-40mmHg) ±5% of reading (41-76mmHg) ±10% of reading (77-99mmHg)
AwRR: ±2rpm
Alarm range: Same as Measurement range
Apnea alarm: YES
External Multi-Gas/O2
Method: Infrared Absorption
Gas sorts: EtCO2, N2O, Des, Iso, Enf, Sev,
Hal O2 (optional, paramagnetic sensor)
Measurement range: EtCO2: 0~10%(0~76mmHg)
N2O: 0~100%
O2: 0~100%
Enf, Iso, Hal: 0~5%
Sev: 0~8%
Des: 0~18%
AwRR: 2-100rpm
Resolution: CO2: 0.1% (1mmHg)
N2O: 1%
O2: 0.1% (1mmHg)
Enf, Iso, Hal, Sev, Des: 0.01%
Resp rate: 1bpm
Data output: Fi and Et Values
Respiration rate: 4~60±1bpm
Other: Up to 3 waveforms displayed
Agent mixture detection
MAC value displayed
NOTE: specifications subject
to change without prior notice
|