VersaMed: iVent 201
Request DemonstrationDownload DatasheetSend for more information


Control Principle: Closed Loop Flow and Pressure Controller


Ventilation Modes:

Adaptive Bi-level

Assist / Control (AC):
• Volume Controlled A/C
• Pressure Controlled A/C*

Synchronised Intermittent Mandatory Ventilation (SIMV):
• Volume Controlled SIMV
• Pressure Controlled SIMV*

Continuous Positive Airway Pressure (CPAP)
Pressure Support Ventilation (PSV)

blob iVent201 Ventilator Model
• iVent 201 IC - Colour screen, pressure, flow and volume waveforms software package, respiratory mechanics software package, pressure control ventilation, internal oxygen mixer with sensor.

 
iVent

Special Modes of Operation:
• Preset Parameters by Patient Weight
• Adaptive Flow™
• Adaptive Time™

• Backup Apnea Ventilation
• Sigh Breath
• Adjustable Rise Time
• Easy Exhale
• 100% O2 Suction

Control Principle: Closed Loop Flow & Pressure Controller
Respiratory Rate 1 to 50 BPM
Tidal Volume 100 to 2,000 ml
Inspiratory Pressure Limit 5 to 80 cm H2O
Inspiratory Time Adaptive Time™ or 0.3 to 3 seconds
Peak Flow Adaptive Flow™ or 1 to 120 L/min Spontaneous up to 180 L/min
Oxygen Mix (FiO2)* 21% to 100%
PEEP 0 to 20 cm H2O
Trigger Sensitivity Flow Sensitivity: 1 to 9 L/min + off
Pressure Sensitivity: -0.5 to -8 cm H2O + off
Pressure Support Ventilation (PSV) 1 to 60 cm H2O


Monitoring and Displayed Parameters:
• Pressure and Flow Waveforms
• Pressure, Flow and Volume Loops*
• Airway Pressure (Analog Bar Graph & Numerical PIP)
• Total Breath Rate (real time & trend)
• Exhaled Tidal Volume (real time & trend)
• Exhaled Minute Volume
• Peak Flow
• Inspiratory Time
• Lung mechanics (Compliance, Resistance)*
• Electrical Power Source (External / Internal)
• Battery Level

* indicates optional feature not available in all iVent 201 models

Size and Weight:
Dimensions
• Height: 12.0 in / 350 mm
• Width: 9.5 in / 240 mm
• Depth: 11.5 in / 290mmWeight (no battery): 17.5 lb / 8 kg

Power:
Battery Weight: 6.5 lb / 3 kg
Overall Weight: 24.0 lb / 11 kgPower Supply:
External AC: 100 to 240V, 50-60Hz, Max 1.6A
External DC: 12 to 15V (Optional: 10 to 30V), Max 8.5A
Internal Battery: Sealed Lead-Acid 12V, 7.2Ah (rechargeable) 1 to 2 hours operating time (dependent on ventilation parameters)

Oxygen (Enrichment) Supply:
• High Pressure Supply: 40 to 60 psi (2.8 to 4.2 bar)
• Low Pressure Supply: Max 80 L/min or 0.5 psi

blob User Adjustable Alarms:
• Rate (High/Low)
• Minute Volume (High/Low)
• Pressure (High/Low)
• Apnea (5 to 120 seconds)
• FiO2 (21 to 100%)
• Leak (0 to 100%)

blob Additional Alarms and Indicators:
High I:E ratio
Low O2 Pressure
AC disconnect
Internal Battery use
Over Temperature
Ventilator Malfunction
Patient Disconnect
Sensor Problem
Date and Time

blob External Interface:
Remote Monitor (VGA)
RS-232 Serial Port, 9 Pin Connector
DIN Keyboard Connector
RJ-45 Remote Alarm Connector

blob Environmental Specifications:
Operating Temperature: -15 to 50 °C / 0 to 120 °F
Storage Temperature: -15 to 70 °C / -4 to 140 °F
Relative Humidity: 15 to 95% at 30 °C / 85 °F
Water Resistance: IP54 (Splash Proof)
Atmospheric Pressure: 430 to 825 mmHg (15000 ft)
Vibration: IEC 68-2-6 and IEC 68-2-34
MIL-STD-810E
Shock: IEC 68-2-27 (100g)
MIL-STD-810E
Total External Sound Level: 40-45 dBa at one metre

blob Standards and Safety Requirements:
Meets the requirements of:
ISO 10651-1: Lung Ventilators for Medical use
ISO 10651-2: Particular requirements for Home Care Ventilators
ISO 10651-3: Particular requirements for Emergency and Transport Ventilators

IEC 60601-1-1: Electrical Safety
IEC 60601-1-2: Electromagnetic Compatibility (EMC)

EN 794-1: Lung ventilators Part 1: Particular requirements for critical care ventilators
EN 794-2: Lung ventilators - Part 2: Particular requirements for home care use
EN 794-3: Lung Ventilators - Particular requirements for Emergency & Transport Ventilators

ASTM F 1100-90: Standard Specification for Ventilators Intended for Use in Critical Care

CSA C22.2 No. 601.1: Medical Electrical Equipment Requirements for Safety
CSA C22.2 No. 601.2: Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Lung Ventilators

UL 2601.1: Medical Electrical Equipment Part 1: General Requirements for Safety

MIL-STD-810E: Environmental Test Methods

IEC 68-2: Basic Environmental Testing Procedures

 

Contact your local Artemis Medical Sales Specialist on 01322 628877 for a demonstration.